AUDIOMETRY & SPIROMETRY
176
0318
Class IIa
Dimensions: 210x297x95 mm
Weight: 1.7 Kg
Internal software and manual
in English/Italian. On request
available in Spanish, French,
Portuguese,German
Spirometry software W20 included
(English, Italian, French, Spanish)
+
DATOSPIR TOUCH - SPIROMETERS
27139
33489
33490
33492
33506
33494
33495
33496
33497
33498
33499
33500
33505
ACCESSORIES FOR SPIROMETERS
Carrying Bag
Turbine transducer - (2) - spare
Fleisch transducer - (1) - spare
Thermal paper - 112 mm
Adult mouthpieces - Ø 28 ext x 65 mm
Pediatric mouthpieces - Ø 21 ext x 70mm
Adaptor for pediatric mouthpiece
SpO
2
pulse oximetry module*
Bronchoconstriction tests*
Int. database for 500 tests w. graphics*
Pmax - Pmax module*
Rechargeable battery
Calibration syringe 3 litres
D
•
•
•
•
•
**
•
•
•
*If ordered separately, please indicate serial number of equipment, necessary to have
access password ** On request
A
•
•
•
•
•
•
•
•
•
•
B
•
•
•
•
•
•
•
•
•
•
•
•
C
•
•
•
•
•
**
•
•
•
•
•
Gimaspir 120
Compatibility of accessories
• 33485 GIMASPIR 120B - Turbine type - with software
• 33487 GIMASPIR 120D - Fleisch type - with software
GIMASPIR 120 spirometers have different types of transducers
(Fleisch or Turbine), a wide liquid crystal back-lit screen and
an internal or external printer. They can incorporate a module
for pulse oximetry measurement (SpO
2
). Software allows
connection to a computer to perform and store the spirometric
tests, or to transfer information.
All the system is controlled by a microprocessor for the acquisition,
calculation and display of alphanumeric and graphic data.
Gimaspir comes complete with transducer (Fleisch or Turbine
type), 100 disposable mouthpieces, noseclip, 2 rolls of thermal
paper, mains power supply, manual and software.
TECHNICAL SPECIFICATION GIMASPIR 120
Type of transducer
FVC, VC, MVV tests in PRE
Bronchoconstriction tests
Graphic incentive for children
Internal data base for graphics tests
Internal printer
External printer connection
Data transfer via Internet with PC of:
- Patients tests - Check-up data - Software upgrade
Tests exportation to other systems
Calibration for quality control or tests
SpO
2
module, MIP.MEP module
Software under Windows to work with PC
Measuring range: Flow from 0 to ± 16 l/s; volume from 0 to 10 1
Flow-Volume accuracy: 5% or 200ml/s - 3% or 50 ml whichever greater (ATS, ERS)
Flow resistance: <0.06 kPa/l/s at 14 l/s (ATS, ERS)
Resistance at 14 l/s: Turbine ≤ 0.125 KPa/lls Fleish ≤ 0.095 KPa/lls
Display: Liquid Crystal Display; 320x240 pixels, Area of 120x90 mm
Data input: Alphanumeric membrane keyboard
Safety standards: IEC 601.1 (EN60601.1), UNE 20-613, IEC 601.1.1 (EN601.1.1)
Power supply: 200-240 V 50/60 Hz (110V on demand)
Power 25 VA (aprox.)
Made in Europe
B
TURBINE
•
•
150 tests
112 mm
Option
•
•
•
Option
•
D
FLEISCH
•
•
•
500 tests
112 mm
•
•
-
•
Option
•
GIMASPIR 120
- SPIROMETERS WITH SOFTWARE
+
STANDARD ACCESSORIES
Spirometry software W20
25 carton mouth piece (33476, 33477 only)
Nose clip
1 reusable mouth piece
2 rolls of thermal paper
25 disposable transducer (33478 only)
USB cable
manual: English, Italian, Spanish
Rechargeable battery
TECHNICAL SPECIFICATIONS
Parameters: FVC, VC, MVV, FEV1, PEF, MEF 25%, MEF 50%, MEF 75%, FEF25-75%, ERV, IRV,
TV, IC, MVV, RESP/MIN, FVC (I), FEV0.5 (I), FEV1 (I), FEV3 (I), FEV0.5/FVC (%), FEV1/FVC (%),
FEV3/FVC (%), FEV1/VC (%), PEF (l/s), MEF25% (l/s), MEF50% (l/s), MEF75% (l/s), FEF75-85%
(l/s), FET25-75% (s), FET100% (s), MEF50%MIF50%, MTT (s), FEV1/FEV0.5, FEV1/PEF (%),
MIF50% (l/s), FIVC (I), FIV1 (I), FIV1/FIVC (%), FEV1/FIV1 (%), PIF (l/s), PEF/PIF, Vext. (I), VC (I),
TV (I), ERV (I), IRV (I), IC (I), Ti (s), Te (s), Tt (s), Ti/Tt (%), MVV (l/min), Br/Min, MVV ind (l/min),
Lung Age, COPD disk
Predicted value: ERS, NHANES III, Knudson, Platino, Morris, SEPAR (Spain), Crapo, Zapletal,
Polgar-Weng, Padilla (Mexico), Gutierrez (Chile), Cruz (Mexico), Golshan (Iran).
Measuring range: Flow from 0 to ±16 l/s; Volume from 0 to 10
Flow-Volume accuracy: 5% or 200m/l - 3% or 50 ml whichever greater (ATS, ERS)
Flow resistance: <0.06 kPa/l/s at 14 l/s (ATS, ERS)
Resistance at 14 l/s: Turbine ≤ 0.125 kPa/l/s Fleish ≤ 0.095 kPa/lls
Display: Colour touchpad Display 640x480 pixels / 116.6x87.8 mm
Safety standard: IEC 601.1 (EN60601), UNE 20-613, IEC 601.1.1 (EN601.1.1)
Power supply: 125-240 V, 50/60 Hz Power 30 VA (approx.) Made in Europe.
Spirometry software W20 included
(English, Italian, French, Spanish)
GIMA
code
ACCESSORIES FOR DATOSPIR TOUCH
Bluetooth module (PC & Printer)
Ethernet module
SpO
2
module
MIP-MEP module
Calibration syringe 3 litres
Compatibility
33476 33477 33478
Disposable transducers
•
Adult mouthpieces - Ø 28 ext x 65 mm •
•
Pediatric mouthpieces - Ø 21 ext x 50 mm •
•
Adaptor for pediatric mouthpieces •
•
Thermal paper - 112 mm
•
•
•
Reusable bacterial filter
•
•
Membrane for bacterial filter
•
•
Fleisch transducer - (1) - spare
•
Turbine transducer - (2) - spare
•
• 33476 DATOSPIR-TOUCH - TURBINE TRANSDUCER
• 33477 DATOSPIR-TOUCH - FLEISCH PNEUMOTACHOMETER
• 33478 DATOSPIR-TOUCH - DISPOSABLE FLOW TRANSDUCER
New digital spirometer with colour touchpad display in three operation
modes: primary care, occupational or diagnostic.
- Internal printer and USB external printer connection
- Optional Bluetooth or Ethernet connectivity
- QWERTY keyboard
- Internal database for more than 6500 tests
- Rechargeable battery
- Electronic weather station (temperature, humidity and pressure)
- F/V & V/T courves
- 3 best tests selectable and printable
- Pediatric incentive and acoustic signal
- Quality control (QC prompts and QC Grades)
- Autodiagnostic (Miller's Quadrant, Kory and Lyons, NHLEP, ATS)
GIMA
code
33470
33479
33480
33483
33505
33502
33506
33494
33475
33492
33501
33504
33490
33489
CONSUMABLES AND SPARES
GIMA
code