ELECTROSURGERY
120
• 30631 DIATERMO MB 120 FLASH
• 30633 DIATERMO MB 200 FLASH
MB FLASH are a High Frequency ElectroSurgical
equipment suitable for precision monopolar and bipolar
surgery and micro-surgery without tissue alterations.
MB FLASH allow surgical treatments with programmable timer
operations up to milliseconds or with traditional mode.
MB FLASH allow pure CUT, cut-coagulation BLEND, incision
with reduced production of eschar ENHANCED, superficial
coagulation FORCED COAG, deep coagulation in absence
of necrosis SOFT COAG and BIPOLAR coagulation. Digital
reading of delivered power and the surveillance through
microcontroller of the operational functions, assure absolute
reliability of the working conditions.
MB FLASH allow a highly professional surgery through
ergonomic and safety features.
Connection of neutral electrode is
constantly monitored.
Safety control of patient/plate
contact using split neutral electrode.
Possibility to control the output functions and the delivery of
output power by handle, allows surgical operation without
diverting attention from the surgical field.
Features:
- Patient to plate contact control
- Split return electrode use allowed
- Minimally invasive surgical treatment allowed
- Monopolar and Bipolar indipendent output
- Auto Start/Stop in Bipolar Coag
- Working condition planning
- Power delivery by pedal and/or handle
- Digital regulation and indication of the output power
- Sound level control
- Adjustable power increment
- RF power pulse emission time setting
- RF power pulse interval setting
It allows selection from pedal of CUT and COAG functions
Antiexplosion and waterproof.
30568
Standard footswitch - 2 m cable
30576
Standard footswitch - 3 m cable
30571
Waterproof MB footswitch - 2m cable
30570
Double MB footswitch - antiexplosion, water proof
30569
Double antiexplosion, water proof footswitch - MB240-380
30572
Double antiexplosion, water proof footswitch - MB250-400-300D-400D
30557
Main board - specify model and serial number of diatermo with order
30558
Output board for MB 240, 250, 380, 400 - specify as above
FOOTSWITCHES FOR MB 240, 250, 300D, 380, 400, 400D
MAIN BOARD
FOOTSWITCHES FOR MB 122, 132, 160, 200, 202
GIMA
code
FOOTSWITCHES AND BOARDS
TECHNICAL SPECIFICATIONS
MB 120F
MB 200F
Max output power CUT
120 W-250 Ω 200 W-250 Ω
Max output power BLEND
90 W-200 Ω 120 W-200 Ω
Max output power ENHANCED
90 W-250 Ω 120 W-250 Ω
Max output power FORCED COAG
80 W-150 Ω 150 W-150 Ω
Max output power SOFT COAG
60 W-100 Ω 90 W-100 Ω
Max output power BIPOLAR COAG
60 W-50 Ω
80 W-50 Ω
Working frequency
600 KHz
600 KHz
RF power pulse emission time
10ms - 30sec 10ms - 30sec
RF power pulse interval
1 - 9
1 - 9
Patient circuit
F
F
Selectable input voltage
115 - 230 Vac 115 - 230 Vac
Mains frequency
50 - 60 Hz
50 - 60 Hz
Electrical input power
300 VA
350 VA
Size WxHxD mm
370x144x319 370x144x319
Weight
6 kg
6 kg
Controls: Patient/Plate circuit monitoring, Output power monitoring,
Self check control
Safety: EN60601-1, EN60601-1-2, EN60601-2-2, Electrical Class: I CF,
MDD 93/42/EC Class: II b
MONOPOLARANDBIPOLARELECTROSURGICALUNITS120WAND160W
OUTPATIENT SURGERY
DERMATOLOGY
VASCULAR SURGERY
GYNECOLOGY
DENTAL
OTORHINOLARYNGOLOGY
PEDIATRIC SURGERY
FIRST AID
PLASTIC SURGERY
ENDOSCOPY
OPHTHALMOLOGY
NEUROSURGERY
PODIATRY
PNEUMOLOGY
UROLOGY
VETERINARY
STANDARD ACCESSORIES
MB two-button autoclave handle
Waterproof MB footswitch (30571) only for 30633
MB operative foot switch only for 30631
MB metal plate (neutral electrode 30566) and cable (30559)
2 disposable ground pads (30562)
Kit 10 short standard electrodes Ø 2.4 mm
3 needle + 3 blade + 3 ball electrodes 7 cm
Power cable 5m
Microsurgery handle (30552)
Microsurgery needles 10 pieces
Manual: English, Italian
30569